[automatic calibration]
Laser Receiver
Laser Receiver Calibration
EZCalibration
Laser
Point: 1
Continue
EZCalibration
Laser
Point: 1
Continue
The procedure consists of passing the laser receiver through the laser beam several times, moving the booms very
slowly.
As usual the chassis has to stay completely stable.
When the beam is intercepted you will hear the horn and the message “Please Wait” will appear.
After a couple of seconds the message “Press Enter” means the unit is ready for a new acquisition.
Move your dipper stick to a new position prior to pressing .
Press and acquire the beam again.
Note:
- Move the booms very slowly!
- Alternate raising or lowering the booms to capture the beam with the receiver.
- Take “extreme” points (e.g. dipper stick far away from the cab or very close to the cab)
- Remember that the laser receiver isn’t able to receive the laser beam when the detection window is almost
horizontal.
- Take at least 10 points, 15 to improve the accuracy.
Enter
Page 60
• Calibration completed! Proceed to Usage section.