- 23 -
EZDigPro
User & Calibration Manual
EXCAVATOR PARTS USED IN CALIBRATION
[calibration]
Part Names
Articulated Boom – 4-Sensor Machine
Boom 1
Boom 2
Boom 3
Chassis
Bucket
To assign a 4-sensor system to a 3-sensor machine
(eg: the next day):
- Skip the assignment procedure and go directly to Calibration.
- When you choose how many sensors will be used, answer: “3 sensors.”
- The system will tell you that it sees “4 sensors.” Enter: “OK” to continue.
- The system will automatically ignore Sensor # 3 from the previous
4-sensor assignment, so do not use the sensor that was on Boom 3.
- Place the sensor that was on Boom 2 (the articulated boom from your first
machine) onto the dipper stick, which is now called Boom 2.
- Sensor 1 will again be on the main boom and Sensor 4, again on the bucket.
If the laser receiver was sensor #3 on the 4-sensor machine
and you want to use it on the 3-sensor machine as well, then you have to re-
assign sensor #3 as the new sensor #2, and sensor #2 as the new sensor #3
(which the system will ignore) prior to entering calibration.
Note: Use the machine data storing function (see: User Options Menu) to avoid re-calibration each time you put the
system on another machine. Also mount the sensors with the support plates if you plan to change machines often.