9.3.1 Lubricants and lubrication points
Lubricate all lubrication points with lubricant during maintenance. Apply lubricant
thinly with a non-linting rag or brush.
Fig. 13
Lubrication point overview GE-25-P
Lubrication point
Lubricant
Metal guide surfaces
Isoflex-Topas NCA 52
NOTICE
Risk of damage due to hardening lubricants!
At temperatures above 60°C lubricants harden faster and the GE-25-P can
be damaged.
Reduce the maintenance interval accordingly.
NOTICE
Risk of damage due to insufficient lubrication!
In the case of continuous short lifting movements, insufficient lubrication can
cause the product to run dry and be damaged.
Run the complete stroke every 1000 cycles or at least once a day.
NOTICE
Risk of corrosion due to ionized air environment
If the electric modules are used in an ionised air environment, there is a risk
that exposed parts could corrode.
Always grease exposed flanges, shafts, guides and jaws regularly.
Afag standard lubrication: Staburax NBU8EP (flat guides), Blasolube 301