Fault elimination
38 – 48
Assembly instructions EN
GE-25-P
Date 02.11.2021
Version 1.0
Fault
Possible cause
Remedy:
GE-25-P does not perform the
full stroke
Dirt accumulation between base
jaws and guide
Screw-on surface not sufficiently
flat
Breakage of components in the
product (e.g. due to overload)
Clean and lubricate GE-25-P (
chap. 9)
Check the mounting surface for
evenness (
chap. 6.3)
Send GE-25-P with repair order to
Afag
GE-25-P opens or closes
jerkily
Not enough lubricant in the
mechanical guide surfaces
Screw-on surface not sufficiently
flat
Loading too large
Clean and lubricate GE-25-P (
chap. 9)
Check the mounting surface for
evenness (
chap. 6.3)
Check the permissible weight and
length of the gripper fingers (
Gripping force too low
Too much lubricant in the
mechanical clearances
Incorrect gripping force
preselection
Clean and lubricate GE-25-P (
chap. 9)
Check setting of the gripping force
Check design of the GE, observe
the max. workpiece weight (
chap.
Opening and closing times are
not achieved
Loading too large
Check the permissible weight and
length of the gripper fingers
Electrical signals are not
transmitted
Cable incorrectly connected
Strands reversed
Check round plug connector for
correct seating
Check PIN assignment
Faults indicated via LED Error
(only with "Digital I/O" variant)
Rotary switch is in intermediate
position (LED flashes for 0.6 s)
Error overtemperature (LED
flashes for 1.2 s)
Warning overtemperature (LED
lights up permanently)
Turn the rotary switch to the marked
position
Wait until GE-25-P has cooled down
Control digital inputs "Open gripper"
and "Close gripper" with High OR:
Disconnect and reconnect the
power supply
LED “Error” goes out. The error is
acknowledged.
When the GE-25-P has cooled
down, the warning is automatically
deleted