Installation, assembly & setting
28 – 48
Assembly instructions EN
GE-25-P
Date 02.11.2021
Version 1.0
The safety instructions in
chap. 2 "Safety instructions" of these assembly
instructions must be observed in addition to the safety instructions contained
in this chapter.
6.2 Installation & Assembly
6.2.1 Mounting of variant «Digital I/O»
1. Check the evenness of the mounting surface (
chap. 6.3).
2. Screw the GE-25-P to the machine/system (
chap. 6.3).
- If necessary, use suitable connecting elements (adapter plates).
- Observe the permissible screw-in depth (
chap. 6.3).
- Observe the tightening torque of the fastening screws (
chap. 6.3).
3. Attach the gripper fingers to the base jaws (
chap. 6.3).
4. Place the cable for sensors on the M8 connector and tighten the threaded
ring hand-tight (
chap. 6.4).
5. If necessary, adjust the gripping force.
6. Mount the sensor (
chap. 6.5).
7. Place the cable for power supply and control on the M8 connector and
tighten the threaded ring hand-tight (
chap. 6.4).
GE-25-P Variant Digital I/O is mounted.
CAUTION
Danger of injury when handling the GE-25-P!
Careless handling of the GE-25-P can cause personal injuries and damage
to the GE-25-P.
Only qualified personnel may work with or on the module!
Observe the assembly instructions!
NOTICE
No liability can be assumed for damages caused by improper
installation/assembling work on the part of the operator.
NOTICE
Avoid overtemperature faults due to too high temperatures!
Excessively high temperatures of GE-25-P can lead to temperature errors.
Ensure sufficient heat dissipation via the screw-on surface.
Mount the GE-25-P in such a way that sufficient cooling is ensured.
The size of the cooling surface depends on the application.
Avoid additional heat input, e.g. through attachments or through the
attached axle.