Maintenance and Repair
40 – 48
Assembly instructions EN
GE-25-P
Date 02.11.2021
Version 1.0
9.3 Maintenance activities and maintenance intervals
The GE-25-P are almost maintenance-free. Nevertheless, some maintenance
work must be carried out to ensure an optimum operating condition of the
electric grippers.
The gripper does not need to be dismantled for maintenance work.
9.3.1 Maintenance intervals
Fig. 12
Maintenance points GE-25-P
No. Maintenance point
Maintenance work
Interval
System
[On/Off]
Remarks
1
GE-25-P
Check
1000 cycles
or daily
[On]
Perform a complete stroke on the GE-25-P
2
Module GE-25-P
Cleaning and
checking
As required
[Off]
Clean the electric gripper with a dry, lint-free cloth.
- Do not spray the electric gripper with water, do not use
aggressive cleaning agents.
Perform a visual inspection of the electric gripper.
3
Metal guide surfaces
Lubricating
2 Million
cycles
[Off]
Lubricate all lubrication points with lubricant (guides:
lubricant Isoflex-Topas NCA 52)
In extreme ambient and operating conditions, shortened maintenance cycles
can ensure that the service life is maintained.