Safety instructions
14 – 48
Assembly instructions EN
GE-25-P
Date 02.11.2021
Version 1.0
2.8.2 Danger due to electricity
2.8.3 Dangers in case of power failure
2.8.4 Mechanical hazards
DANGER
Danger! Risk of electric shock!
If work on electrical components is required, ensure that the work is carried
out properly, failure to do so will cause serious or fatal injuries.
Work on the machine's electrical equipment may only be performed by
skilled electrician or trained personnel under the supervision of a skilled
electrician in accordance with all relevant electrical regulations.
Before connecting or disconnecting electrical lines and before assembly,
conversion, maintenance and adjustment work, switch off the power supply
and secure it against being switched on again.
When the power supply is connected, do not touch the connection points of
the GE-25-P and do not move any parts by hand.
Cover live parts.
WARNING
Risk of injuries due to uncontrolled parts movements!
If the power supply is switched on or there is still residual energy in the
system, unexpected movements when working on the GE-25-P can cause
serious injuries.
Switch off the power supply and use a lockout device to make sure that the
system cannot be switched on again.
Ensure that there is no residual energy left in the system.
WARNING
Risk of injury from falling objects if the power supply fails!
Electronic products are fundamentally not fail-safe. If the power supply fails,
the gripping force drops and it cannot be guaranteed that the gripped
workpiece is held securely.
The operator is responsible for ensuring that the drive is brought to a safe
state in the event of a power supply failure.
WARNING
Risk of injury - Do not reach into the system during operation!
There is a risk of injury if the personnel reaches into the system during normal
operation.
Never reach into the system during normal operation!