42
Calibrate both the analyzers to 20.9 as follow:
please read analyzer manual for more specific instructions, especially if analyzers will be located in a
hot and/or high humidity area.
- Remove the fitting covering the sensor “a”
(Fig. 49);
- Remove the fitting covering the sensor “b”
(Fig.49).
- Expose the sensor to ambient air for approximately (15) seconds.
- Adjust the meter until the reading “c”
stabilizes to 20.9% (Fig. 50).
- Re-connect the sensor fitting to the analyzer.
WARNING
Never connect an O
2
analyzer directly to a high or low pressure air/nitrox source.
49
8.3
Calibrate analyzers
50
Start up
c