background image

100L V-TWIN DIRECT DRIVE COMPRESSOR 3HP 

MODEL NO: 

SAC10030VE.V2

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

IMPORTANT:

 PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE 

THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR 
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

1.  SAFETY

1.1.    

ELECTRICAL  SAFETY

 

‰

  

WARNING!

 It is the user’s responsibility to check the following:  

  Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and all  

  electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical  

  products. You may obtain an RCD by contacting your local Sealey stockist. If the product is used in the course of business duties, it  

  must be maintained in a safe condition and routinely PAT (Portable Appliance Test) tested.  

 

ELECTRICAL SAFETY INFORMATION It is important that the following information is read and understood.

1.1.1.   

Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. 

1.1.2.   

Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.

1.1.3. 

  

IMPORTANT:

 Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the  

 

correct fuse - see fuse rating in these instructions.

 

8

  

DO NOT

 pull or carry the appliance by the power cable and 

DO NOT

 pull the plug from the socket by the cable. 

 

8

   DO  NOT

 use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired or is replaced immediately by  

  a qualified electrician.

1.1.4. 

  

This product is fitted with a BS1363/A 13 Amp 3 pin plug. 

        

If the cable or plug is damaged during use, switch the electricity supply and remove from use. 

        

Ensure that repairs are carried out by a qualified electrician.

        

Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.

 

A) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

B) Connect the BROWN live wire to the live terminal ‘L’.

 

C) Connect the BLUE neutral wire to the neutral terminal ‘N’.

       

Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight. 

        

Sealey recommend that repairs are carried out by a qualified electrician.

 

IMPORTANT!

 The use of extension leads to connect these compressors to the mains is not  

 

recommended as the resulting voltage drop reduces motor, and therefore pump performances.

1.2.    

GENERAL  SAFETY

 

9

 

 

Familiarise yourself with the application and limitations of the compressor.  

 

9

 

 

Ensure the compressor is in good order and condition before use. If in any doubt 

DO NOT

 use the unit and contact an electrician/   

  service agent.

 

‰

   WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust, pressure  

  switch or safety valve.

 

9

 

 

Before moving, or maintaining the compressor ensure it is unplugged from the mains supply and that the air tank pressure has been vented.

 

 

9

 

 

Maintain the compressor in good condition and replace any damaged or worn parts. Use genuine parts only. 

Unauthorised parts may  

  be dangerous and will invalidate your warranty.

 

9

 

 

Read the instructions relating to any accessory to be used with the compressor. Ensure the safe working pressure of any air  

 

  appliance used exceeds unit’s output pressure. If using spray gun, check that the area selected for spraying is provided with air change    

  system/ventilation.

 

9

 

 

Ensure the air supply valve is turned off before disconnecting the air supply hose.

 

9

 

 

To move the compressor use the handle only. Maintain unit’s centre of gravity when lifting. 

DO NOT

 attempt to lift or move the  

 

  compressor by any other means.

 

9

 

 

Use the compressor in a well ventilated area and ensure it is placed on a firm surface.

 

9

 

 

Keep tools and other items away from the compressor when it is in use, and keep the area clean and clear of unnecessary items.

 

9

 

 

Ensure any air hose attached is not tangled, twisted or pinched.

 

9

 

 

Keep children and unauthorised persons away from the working area.

 

8

 

 

DO NOT

 dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

 

8

 

 

DO NOT

 use the compressor outdoors, in damp or wet locations or operate within the vicinity of flammable liquids, gases or solids.

 

8

 

 

DO NOT

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time    

  after shut down. 

 

8

 

 

DO NOT

 attempt to move the compressor by pulling the air tool hose. 

 

8

 

 

DO NOT

 use this product to perform a task for which it is not designed.

 

8

 

 

DO NOT

 deface the certification plate attached to the compressor tank

 

8

 

 

DO NOT

 cover the compressor or restrict air flow around the machine whilst operating.

S

AC10030VE.V2 Issue 2 (7) 24/06/20

Original Language Version

© Jack Sealey Limited

Refer to 

instructions

Wear eye 

protection

Wear ear 

protection

Ensure oil level 

is correct before 

first use

WARNING:

High Voltage

WARNING:

Hot surface

WARNING:

Automatic 

start up

Indoor use only

DO NOT

 open 

the air cock 

before an air 

hose is attached

RECOMMENDED  

FUSE RATING: 

13AMP

Summary of Contents for SAC10030VE.V2

Page 1: ... a qualified electrician IMPORTANT The use of extension leads to connect these compressors to the mains is not recommended as the resulting voltage drop reduces motor and therefore pump performances 1 2 GENERAL SAFETY 9 Familiarise yourself with the application and limitations of the compressor 9 Ensure the compressor is in good order and condition before use If in any doubt DO NOT use the unit an...

Page 2: ...ashers supplied 4 5 Attach handle with screw provided 4 6 The compressor should be operated on a flat firm surface or one that does not exceed 5 either transversely or longitudinally fig 1 and should be in a position that allows good air circulation around the unit 4 7 Remove the plastic transit plug from the oil filler hole 4 8 Before using the compressor check the oil level by referring to the o...

Page 3: ...of the motor fig A Z The reset button is on the side of the box Should the trip activate leave for 1 minute before pressing the button to reset For possible causes of trip activation and remedies see section 7 Troubleshooting 6 MAINTENANCE WARNING Before performing any maintenance operation switch off the compressor disconnect from electricity supply and release all air from the tank In order to k...

Page 4: ...TABLE Maintenance Daily 100 hours 200 hours 500 hours Drain condensation Check Oil level Clean Intake filter Check for Oil leaks Check Cut out Replace Oil Replace air filter Check tube fittings and electrical connections FAULT CAUSE REMEDY Pressure drop in the tank 1 Air leaks at connections 2 Air leaks from safety valve 3 Air leaks from cylinder head gasket 1 Run compressor to maximum pressure sw...