background image

  1.  SAFETY INSTRUCTIONS

1.1.   ELECTRICAL SAFETY 

 

  

WARNING! 

ElEctrical installation of comprEssor to a 3-phasE 415 Volt supply must only bE  

 

carriEd out by a qualifiEd ElEctrician. 

make sure the power supply cable is correctly connected to the earth. it  

 

is the user’s responsibility to read, understand and comply with the following: 

 

You must check all electrical equipment and appliances to ensure they are safe before using. You must inspect power supply leads, plugs 

 

and all electrical connections for wear and damage. You must ensure the risk of electric shock is minimised by the installation of  

 

 

appropriate safety devices. An RCCB (Residual Current Circuit Breaker) should be incorporated in the main distribution board.  

 

you must

 also read and understand the following instructions concerning electrical safety. 

1.1.1.  The 

Electricity  at  Work  act  1989

  requires  all  portable  electrical  appliances,  if  used  on  business  premises,  to  be  tested  by 

 

a qualified electrician, using a Portable Appliance Tester (PAT), at least once a year.

1.1.2.  The 

health  &  safety  at  Work act  1974

  makes  owners  of  electrical  appliances  responsible  for  the  safe  condition  of  the  appliance 

 

and the safety of the appliance operator. 

if in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure insulation on all cables and the product itself is safe before connecting to mains power supply. 

1.1.4.  Ensure that cables are always protected against short circuit and overload.

1.1.5.  Regularly inspect power supply, leads, plugs and all electrical connections for wear and damage, 

 

especially power connections, to ensure that none is loose. 

1.1.6. 

important:

 

Ensure the voltage marked on the product is the same as the electrical power supply

 

to be used. A three phase plug must be fitted to this machine.

1.1.7.  DO NOT pull the powered appliance by the power cable. 

1.1.8.  DO NOT pull power plugs from sockets by the power cable.

1.1.9.  DO NOT use worn or damage leads, plugs or connections. Immediately replace or have repaired by 

 

a qualified electrician. 

1.1.10.

 

this product must be fitted with a 3-phase plug according to the diagram, and will 

 

require a minimum of 16 amps per phase, (preferably 32 amp) electrical supply. 

 

you must contact a qualified electrician to ensure an appropriately fused supply is available. 

 

Connect GREEN/YELLOW wire to earth       (E) terminal.

 

Connect BROWN wire to L1 (or R1) terminal.

 

Connect BLUE wire to L2 (S2) terminal.

 

Connect the BLACK wire to L3 (T3) terminal. 

 

When completed, check that there are no bare wires, that all wires have been connected 

 

correctly, that the cable external insulation extends beyond the cable restraint and that the restraint is tight.

1.1.11.  DO NOT use this product with a standard extension cable. Only use an ARMOURED extension cable.

INsTRuCTIONs fOR:

BELT DRIvEN COMPRESSORS

mODEL No's

:

 

SA3015/55, SA3020/55 & SA3027/75

Thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions 

and properly maintained, give you years of trouble free performance.

important:

 

PLEASE  READ  THESE  INSTRUCTIONS  CAREFULLY.  NOTE  THE  SAFE  OPERATIONAL  REQUIREMENTS,  WARNINGS  AND 

CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY 

CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INvALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2.   GENERAL SAFETY INSTRUCTIONS

• 

familiarise yourself with the application and limitations of the compressor.     

• 

Ensure that the compressor is in good order and condition before use. If in any doubt do not use the unit and contact an electrician/service  

  agent.

• 

IMPORTANT!

 The compressor must be installed and commissioned by qualified personnel.

  WARNING! Compressor must only be serviced by an authorised agent. DO NOT tamper with, or attempt to adjust,  pressure switch  

  or safety valve.

• 

Before moving or maintaining the compressor

 

ensure it is unplugged from the mains supply and that the air tank pressure has been vented. 

• 

Only use recommended attachments and parts. To use non-recommended items may be dangerous and will invalidate your warranty.

• 

Read the instructions regarding any accessory used with the compressor. Ensure the safe working pressure of any air appliance used  

 

  exceeds the compressor regulator. If using a spray gun, check the area selected for spraying is provided with an air change system or  

 

  ventilation.

• 

Ensure the air supply valve is turned off before disconnecting the air supply hose.

• 

use the compressor in a well ventilated area and ensure it is placed on a firm surface away from any heat sources.

• 

Keep tools and other items away from the compressor when it is in use and keep area clean and clear of unnecessary items.

• 

Ensure the air hose is not tangled, twisted or pinched.

• 

Keep children and unauthorised persons away from the working area. 

• 

DO NOT

 dis-assemble compressor for any reason. The unit must be checked by qualified personnel only.

•  DO NOT

 use the compressor outdoors, or in damp, or wet, locations and DO NOT operate within the vicinity of flammable liquids, gases or  

  solids.

•  DO NOT

 touch compressor cylinder, cylinder head or pipe from head to tank as these may be hot and will remain so for some time after    

  shutdown.

•  DO NOT

 attempt to move the compressor by pulling the air tool hose. 

•  DO NOT

 use this product to perform a task for which it has not been designed.

•  DO NOT

 operate the compressor with the belt guard removed.

Original Language Version

sA3015/55, sA3020/55, sA3027/75    Issue: 2 - 21/10/09

Summary of Contents for SA3015/55

Page 1: ...is tight 1 1 11 DO NOT use this product with a standard extension cable Only use an ARMOURED extension cable Instructions for Belt Driven COMPRESSORs mODEL No s SA3015 55 SA3020 55 SA3027 75 Thank you for purchasing a Sealey product Manufactured to a high standard this product will if used according to these instructions and properly maintained give you years of trouble free performance IMPORTANT ...

Page 2: ... the specifications chart Section 2 WARNING Ensure that you have read understood and apply Section 1 safety instructions and that the unit is wired correctly 4 1 Make sure the main switch fig 3 1 is in position O off and the air outlet valves from the tank are closed 4 2 Plug the lead into mains supply and start the compressor by turning the main switch to I Auto 4 3 Make sure that pressure in the...

Page 3: ...ly if the compressor operates in a very dusty atmosphere a Check oil level and if necessary top up b Remove the filter element fig 6 X by unscrewing wing nut and lowering the air filter cover Clean by blowing through with an air line at low pressure from the clean side Do not operate compressor without filter as foreign bodies or dust could damage the pump c Check belt tension d Check for oil leak...

Page 4: ...ING Maintenance Operations Weekly 3 Monthly Monthly Drain condensation Check oil level Clean intake filter Check belt tension Check tank for internal corrosion Check for oil leaks Maintenance Operations 500 hrs 1000 hrs Check condition of belt and pulleys Check tube fittings and electrical connections Replace oil Internal external inspection of tank General cleaning of compressor Replace air filte...

Reviews: