45
After filling, the cylinders must not be
emptied completely, even during winter
storage, to prevent damp air from getting
in (Fig. 51).
3 Check the condition of the hoses and the relative attachments.
See paragraph 6.2.2 “Connecting the filling hoses”.
AUTOMATIC CONDENSATE DISCHARGE
4 For the models provided with an
automatic condensate discharge,
a special condensate collection
tank has been fitted in the side
compartment of the compressor
(Fig. 52).
The outlet of water vapourized with
lubricating oil should be considered
normal during filling: the quantity is
in direct relation to the percentage of
humidity present in the air.
The condensate must be disposed
of according to the instructions given
in chapter 10.2 “Disposal of waste”.
Use
51
52
Summary of Contents for MCH 14 TECH NITROX SERIES
Page 31: ...31 Installation 3 Pass the pipe through the hole located in the rear guard Fig 29 30 28 29 ...
Page 80: ...80 Troubleshooting 12 1 1 Low pressure compressor ...
Page 85: ...85 Compression diagram High pressure compressor only air Machine diagrams 14 2 ...
Page 86: ...86 Machine diagrams 14 3 Electrical diagram ...
Page 87: ...87 Machine diagrams ...
Page 104: ...104 Pulley Crankcase and cylinder Low pressure compressor Spare parts ...
Page 105: ...105 Piston rod unit Low pressure compressor Spare parts ...
Page 106: ...106 Cylinder Valve and Filter unit Low pressure compressor Spare parts ...
Page 107: ...107 Pump unit Low pressure compressor Spare parts ...