57
Use
If an emergency situation should arise during the
filling of the cylinders, press the “OFF” button
located on the control board (Fig. 79).
The machine is provided with an emergency system that automatically blocks it when:
1) the pressure set on the pressure switch is reached;
2) there is a temporary cut in the power supply;
3) the heat release of the electric motor trips due to an overload.
After an emergency stop and before proceeding with a subsequent operation, it is necessary to check
that the cause of the emergency has been eliminated.
79
SHUTDOWN STEPS
1. After filling is complete, close tank.
2. HP Compressor and LP compressor will automatically shut down at 220 bar (3200 psi).
3. Turn off LP feed air switch. Membrane system and LP filtration will automatically drain.
4. Vent fill whips at the yoke.
5. Remove fill whip from nitrox bottle/tank.