39
The oil is added by removing the two oil caps
located on the upper cover of the machine
(Fig. 41) unscrewed.
The quantity of oil to be poured in is 1.5 lt. for the
high pressure compressor and 2 lt. for the low
pressure compressor and the level should be
checked with the machine turned off, bearing in
mind that an excess amount of oil may cause
infiltrations in the cylinders and a deposit on the
valves. On the contrary, if the oil level is too low,
the pin of the connecting rod is prevented from
providing the correct lubrication with the possibility
of causing a seizure of the cylinders.
To check the quantity of oil poured in, see the
following paragraph.
1 Turn on the manual condensate discharge
taps (Fig. 42).
Start up
8.2
C h e c k s
42
41
43
2 Turn the machine on by moving the general
switch to the “ON” position. Check that the
machine has been switched on by looking to
see the red light of the “OFF” buttons (Fig.43).
3 Run the compressors for about 10 minutes
then leave it at a standstill for 20 minutes.
Summary of Contents for MCH 14 TECH NITROX SERIES
Page 31: ...31 Installation 3 Pass the pipe through the hole located in the rear guard Fig 29 30 28 29 ...
Page 80: ...80 Troubleshooting 12 1 1 Low pressure compressor ...
Page 85: ...85 Compression diagram High pressure compressor only air Machine diagrams 14 2 ...
Page 86: ...86 Machine diagrams 14 3 Electrical diagram ...
Page 87: ...87 Machine diagrams ...
Page 104: ...104 Pulley Crankcase and cylinder Low pressure compressor Spare parts ...
Page 105: ...105 Piston rod unit Low pressure compressor Spare parts ...
Page 106: ...106 Cylinder Valve and Filter unit Low pressure compressor Spare parts ...
Page 107: ...107 Pump unit Low pressure compressor Spare parts ...