“User Configuration” submenu allows you to set access levels and create users to operate the
AEQ CAPITOL mixing Console.
The display in this submenu shows the list of registered users and their associated parameters:
•
“
User
”
:
alphanumeric name of the user. The maximum number of digits is limited to 32.
•
“
Password
”
:
password associated with the user: number combination of up to 32 digits
from zero to nine, although a
maximum of 6 digits
is recommended (a password with
more than 6 digits could be used just to access the software, but couldn’t be used in the
console). This password is used to access all the permitted actions in advanced menu,
from the main screen of the Control and Monitoring section of AEQ CAPITOL. For more
information see section 3.2 of this manual.
•
“
Access Level
”
:
user level associated with the name and password previously
configured (you can check the password associated to a user by means of edition
button). AEQ CAPITOL allows up to 4 different users levels:
o
LEVEL 0:
users with no associated password. The operation is limited to
raising and lowering faders, activate/deactivate the 4 routing keys and the CUE
key of each channel, activate/deactivate channels (“CHANNEL ON/OFF”) and
use the programmable keys and monitoring section. It’s not possible to define
users of this level in the configuration software (you can access to this level in
AEQ CAPITOL console by pressing the “LOGOU” contextual key in the initial
menu).
o
LEVEL 1:
these users may perform the same actions as the level 0 users, and
can also activate equalizers and filters, modify audio input channels gains and
modify the signal present in a certain channel. They can’t modify phase and
balance, activate dynamics processes or modify the routing.These users are
defined in the configuration software with “
Basic
” access level and the
indication “BASIC” is shown in the initial screen of the control surface to identify
this level.
o
LEVEL 2:
these users may perform the same actions as the level 1 users, as
well as all the additional operation, configuration and control options that AEQ
CAPITOL control surface and its associated internal menu offers, except the
change of the
IP address
of the network port (“LAN”) present in the rear panel
of the unit. These users are defined in the configuration software with
“
Advanced
” access level and the indication “ADVAN” is shown in the initial
screen of the control surface to identify this level.
o
LEVEL 3:
this is the highest level in the system, reserved for administrators. It
enables full access to all the equipment menus and configuration options
(including the change of the
IP address
of the network port of the unit), and, in
addition, is the only level enable to access to the configuration software. The
same password is used in this menu integrated into the control surface and in
remote configuration software. These users are defined in the configuration
software with “
Administrator
” access level and the indication “ADMIN” is
shown in the initial screen of the control surface to identify this level. The
password supplied by default for “
ADMIN
” user is
1234.
•
“
ID
”
:
internal referente number for each user automatically and sequentially assigned.