AEQ
CAPITOL
Ultra-compact digital audio mixer
24
2.2.2.3. Control and studio monitors.
AEQ CAPITOL includes line-level monitoring outputs for a pair of speakers in the control room
and another pair for studio or cabin. These outputs are available through a female DB15
connector labelled “
CRM & SRM
”.
Control / Studio Monitoring Outputs (SUB-D female, 15 pins):
Pin Signal Pin Signal
1 CRM
L+ 9 CRM
L-
2 GND 10 GND
3
CRM R+
11
CRM R-
4 GND 12 GND
5
SRM L+
13
SRM L-
6 GND 14 GND
7
SRM R+
15
SRM R-
8 GND
In order to make installation process easier, AEQ offers specific pre-fabricated cable kits for
AEQ CAPITOL audio input/output, both analog and digital, as well as studio headphones: FR
CAB INP, consisting in a male DB15 connector soldered to 4 balanced and shielded 6 meters
long paired cables with no connectors at the other end, for 4 inputs or outputs. For more
information please check chapter 2.2.6 of this manual.
AEQ can upon request provide fully finished cables and in special lengths. For more information
please refer to AEQ sales department or authorised distributors.
2.2.2.4. CUE.
AEQ CAPITOL includes a professional stereo audio output for CUE or prelisten on TRS 3,5 mm
⅛
” jack, unbalanced connection. This connector has been chosen to simplify the selection of
this component among a wide range of cost-effective solutions.
2.2.2.5. Studio headphones.
AEQ CAPITOL features an output for Studio headphones on the DB15 female connector
labelled “
STUDIO H/PHONES
”.
Studio Headphones Output (SUB-D female, 15 pins):
CRM: Control Room Monitor
SRM: Studio Room Monitor
L: Left
R: Right
Common GND
Right
Left