17
EKI-9228G Series User Manual
There are two power inputs for normal and redundant power configurations. The
power input 2 is used for wiring a redundant power configuration. See the following
for terminal block connector views.
Figure 2.14 Terminal Receptor: Power Input Contacts
To wire the power inputs:
Make sure the power is not connected to the switch or the power converter before
proceeding.
1.
Insert a small flat-bladed screwdriver in the V1+/V1- wire-clamp screws, and
loosen the screws.
2.
Insert the negative/positive DC wires into the V+/V- terminals of PW1. If setting
up power redundancy, connect PW2 in the same manner.
3.
Tighten the wire-clamp screws to secure the DC wires in place.
Figure 2.15 Installing DC Wires in a Terminal Block
2.10
Reset Button
Reset configuration to factory default:
Press and hold Reset button for 5 seconds.
System reboot:
Press and hold Reset button for 3 seconds.
V+ V-GND
PWR2
V+ V-GND
PWR1
V+
PWR2
V- GND
V+
PWR2
V- GND
Loosening
Wire-clamp
Screws
Installing DC
Wires
Securing
Wire-
clamp Screws
Note!
Do NOT power off the Ethernet switch when loading default settings.
Summary of Contents for EKI-9228G-8CMI
Page 1: ...User Manual EKI 9228G Series 16xRJ45 4xSFP 8xCombo Port Full Gigabit L2 Managed Switch...
Page 18: ...EKI 9228G Series User Manual xviii A 1 Troubleshooting 305...
Page 19: ...Chapter 1 1Product Overview...
Page 23: ...Chapter 2 2Switch Installation...
Page 36: ...Chapter 3 3Configuration Utility...
Page 41: ...Chapter 4 4Managing Switch...
Page 322: ...Appendix A ATroubleshooting...