![Advantech ASR-5300I Series User Manual Download Page 60](http://html1.mh-extra.com/html/advantech/asr-5300i-series/asr-5300i-series_user-manual_2858386060.webp)
ASR-5300I Series Hardware User Manual
50
3.5.3
Single-Controller with Fault-Tolerant Path
Note!
In the event of single-controller failure, a logical drive is accessed
through the host IDs managed by the alternate RAID controller. Host IDs
and port IPs do not failover to the surviving controller. Therefore, the
EonPath multipath driver is necessary for path redundancy and
controller failover.
Component
Description
RAID system
iSCSI RAID managed by a single controller, with 4 host ports
HBA or NIC
iSCSI initiators, preferably PCI-E TCP/IP offload engine (TOE)
capable cards
GbE cables
GbE network cables
Software
EonPath to manage the fault-tolerant paths with failover/ failback
and load balance
RAID configuration
4 logical partitions (created from 2 logical volumes)
2 logical volumes (each contains a logical drive)
2 logical drives
* Each logical partition appears on two different host links for fault
tolerance. Use EonPath multipath software to ensure the operating
system can identify alternate paths to the same logical drive.
Summary of Contents for ASR-5300I Series
Page 1: ...User Manual ASR 5300I Series Hardware...
Page 10: ...ASR 5300I Series Hardware User Manual x...
Page 11: ...Chapter 1 1 Introduction...
Page 25: ...Chapter 2 2 Hardware Installation...
Page 42: ...ASR 5300I Series Hardware User Manual 32...
Page 43: ...Chapter 3 3 System Connection...
Page 74: ...ASR 5300I Series Hardware User Manual 64...
Page 75: ...Chapter 4 4 System Monitoring...
Page 87: ...Chapter 5 5 System Maintenance...
Page 104: ...ASR 5300I Series Hardware User Manual 94...
Page 105: ...Appendix A A Technical Specifications...
Page 110: ...ASR 5300I Series Hardware User Manual 100...
Page 111: ...Appendix B B Certifications...
Page 113: ...Appendix C C Slide Rail Kit Installation Guide...