Installing the RAID Controller
After installing the BBU and FBM, the RAID controller can be re-inserted into the
enclosure:
1.
Insert the controller slowly into the module slot. When you feel the contact
resistance, use slightly more force and then push both of the ejection levers
upwards (as indicated with the blue arrows below) to secure the controller in the
chassis.
2.
Secure the controller by fastening the two retention screws
(1)
under the
ejection levers
(2)
.
Note!
A new or replaced BBU requires at least 12 hours to charge to full
capacity.