41
ASR-5300I Series Hardware User Manual
Chapter 3
S
ystem
Connection
3.3.6
Switched Fabric Connection (Dual-Controller)
A channel link bypass is provided on external FC switches. Every application server
shown in the diagram is equipped with two HBAs with FC links via two FC switches
connected to the SFP ports on individual RAID controllers.
Note!
A logical partition presented through LUN Mapping can be seen by all
servers across SAN. Ensure users have access control, such as
file-locking, switch zoning, port binding, etc., to avoid access contention.
Channels
Controller A
Controller B
Host
CH0, CH1, CH2, CH3
CH0, CH1, CH2, CH3
Configuration Information
RAID controller
2
Host server
4 (or more via FC switches)
FC switch
2 (or 1 into 2 zones)
Data path connection
Fault-tolerant paths
Host channel bandwidth
6400 MB/s