Section 3 Engineering Guidelines
TRACER 6000 Series Split System Manual
36
Copyright © 2005 ADTRAN, Inc.
612806320L1-1B
To ODU Interface (N-Type Connector)
The
TO ODU
interface (N-type connector) is the IDU-side IF connection between the IDU and ODU. The
IDU transmits payload data to the ODU on a 280 MHz carrier and receives the ODU data on a 140 MHz
carrier. The IF connection also provides a full-duplex control and monitoring channel between the IDU and
ODU on a 4.5 MHz carrier. Additionally, this interface provides DC power to the ODU, taken directly
from the voltage supplied to the power connection on the rear of the IDU. The power supply is protected
from a short-circuit on the IDU/ODU connection via a thermal protection device.
5.
TRACER 6320 OUTDOOR UNIT (ODU)
Figure 3 identifies the features of the TRACER 6320 ODU bottom panel and Table 10 provides a brief
description of each interface.
Figure 3. TRACER 6320 ODU Bottom Panel
Table 10. ODU Bottom Panel Description
Name
Connector
Description
A
Antenna
N-type (female)
Antenna feedline cable connection
B
GND
Bantam
Ground reference for the RSSI interface
C
RSSI
Bantam
DC voltage indicating strength of the received signal at the
antenna
D
Cover
N/A
Weather-proof (removable) cover for protecting
GND
and
RSSI
interfaces
E
To IDU
N-type
Feedline cable for connecting to the Indoor Unit
Antenna
Connector
A
GND
B
RSSI
C
Weather-proof
Cover for RSSI and GND
D
Connection
to IDU
E