Section 7 MIBs
TRACER 6000 Series Split System Manual
110
Copyright © 2005 ADTRAN, Inc.
612806320L1-1B
TRACER.mib adTRACERBPVoff
a change in the BiPolar Violation (BPV) state has
occurred and the BPV alarm is inactive.
adTRACERRAoff
a change in the Frame RA (Remote Alarm) state has
occurred and the RA alarm is inactive.
adTRACEROOFoff
a change in the Out Of Frame (OOF) state has occurred
and the OOF alarm is inactive.
adTRACERCVoff
a change in the Code Violation (CV) state has occurred
and the CV alarm is inactive.
adTRACERCRCoff
a change in the Cyclic Redundancy Check (CRC) state
has occurred and the CRC alarm is inactive.
adTRACERmfLOFoff
a change in the Loss of Multiframe (LOMF) state has
occurred and the LOMF alarm is inactive.
adTRACERmfLOSoff
a change in the Multiframe Loss of Signal (LOS) state
has occurred and the Multiframe LOS alarm is inactive.
adTRACERmfAISoff
a change in the Multiframe Alarm Indication Signal (AIS)
state has occurred and the Multiframe AIS alarm is
inactive.
adTRACERmfRAoff
a change in the Multiframe Remote Alarm (RA) has
occurred and the Multiframe RA alarm is inactive.
adTRACERlineLoopbackOff
a change in the line loopback state has occurred and the
line loopback is inactive.
adTRACERlinkLoopbackOff
a change in the link loopback state has occurred and the
link loopback is inactive.
adTRACERLinkDown
the RF link is down.
adTRACERLinkUp
the RF link is up.
adTRACERRFCLinkDown
the RFC link is down between the Indoor Unit (IDU) and
Outdoor Unit (ODU). This trap only applies to TRACER
split systems.
adTRACERRFCLinkUp
the RFC link is up between the IDU and ODU. This trap
only applies to TRACER split systems.
adTRACERRxLow
the receive level is within 10 dB of sensitivity and the RF
Low alarm is active.
adTRACERRxLevel
a change in receive level has occurred and the receive
level is within normal range.
adTRACERcurrThrsESon
the threshold for current Errored Seconds (ES) has been
exceeded.
adTRACERcurrThrsESoff
the threshold for current ES has not been exceeded.
adTRACERcurrThrsSESon
the threshold for current Severely Errored Seconds
(SES) has been exceeded.
adTRACERcurrThrsSESoff
the threshold for current SES has not been exceeded.
Table 3. Traps Supported by the TRACER 6000 split system (Continued)
MIB
Trap
This trap indicates that....