Section 5 User Interface Guide
TRACER 6000 Series Split System Manual
76
612806320L1-1B
> T1
X
S
TATUS
/C
ONFIGURATION
/L
OOPBACK
> L
OOP
/N
ORMAL
S
TATE
> L
INK
[L
OCAL
]
Activates a loopback at the local TRACER T1 framer towards the remote end of the wireless link (see
Figure 21). Use the local
L
INK
loopback to loop the data transmitted from the remote end of the link back
across the radio link to the remote end of the link. This loopback tests the integrity of the radio link and all
the associated digital and RF hardware.
Figure 21. T1 Local Link Loopback
> T1
X
S
TATUS
/C
ONFIGURATION
/L
OOPBACK
> L
OOP
/N
ORMAL
S
TATE
> L
INK
[R
EMOTE
]
Activates a loopback at the remote TRACER T1 framer towards the local end of the wireless link (see
Figure 22). Use the remote
L
INK
loopback to loop the data transmitted from the local end of the link across
the radio link to the local end of the link. This loopback tests the integrity of the radio link and all the
associated digital and RF hardware.
Figure 22. T1 Remote Link Loopback
> T1
X
S
TATUS
/C
ONFIGURATION
/L
OOPBACK
> L
OOP
/N
ORMAL
S
TATE
> L
INE
[L
OCAL
]
Activates a loopback at the local TRACER T1 framer towards the connected T1 equipment (see Figure 23).
Use the local
L
INE
loopback to test data path integrity from the local TRACER unit to the connected T1
equipment.
Figure 23. T1 Local Line Loopback
> T1
X
S
TATUS
/C
ONFIGURATION
/L
OOPBACK
> L
OOP
/N
ORMAL
S
TATE
> L
INE
[R
EMOTE
]
Activates a loopback at the remote TRACER T1 framer towards the connected T1 equipment at the remote
end of the link (see Figure 24). Use the remote
L
INE
loopback to test data path integrity from the remote
TRACER unit to the T1 equipment connected at the remote end of the link.
Figure 24. T1 Remote Line Loopback