TRACER 6000 Series Split System Manual
Section 5 User Interface Guide
612806320L1-1B
69
> D
ATAPATH
P
ROVISIONING
Figure 11 shows the Datapath Provisioning menu page, which displays the active network interfaces for
the installed modules (from both the local and remote TRACER units).
Figure 11. Datapath Provisioning
> D
ATAPATH
P
ROVISIONING
> T
OTAL
A
CTIVE
C
HANNELS
Defines the total number of channels active on the installed modules. Specify
2
,
4
, or
8
total active
channels. After defining the total number of active channels, specify the actual active channels using the
C
HANNEL
S
ELECTION
menu.
> D
ATAPATH
P
ROVISIONING
> M
ODULE
1/M
ODULE
2 C
HANNELS
(Read Only) Displays the total number of active channels on the installed module.
> D
ATAPATH
P
ROVISIONING
> C
HANNEL
S
ELECTION
Defines the active channels (
A
,
B
,
C
,
D
) on each installed T1 module or the bandwidth dedicated to the
Quad Ethernet Switch module (in 2 Mbps steps). To activate a channel, press
<Enter>
and use the
spacebar or arrow keys to cycle through the available channel combinations until the desired combination
displays. Press
<Enter>
again to make the channel combination change. If the specified channel selection
is not valid, the TRACER automatically corrects the configuration and populates the field with a valid
selection.
The number of active channels and the channel configuration on both the local and remote
systems must match for the RF link to function properly. A discrepancy between the systems
can result in unpredictable operation.
The number of active channels and the channel configuration on both the local and remote
systems must match for the RF link to function properly. A discrepancy between the systems
can result in unpredictable operation.