TRACER 6000 Series Split System Manual
Section 3 Engineering Guidelines
612806320L1-1B
Copyright © 2005 ADTRAN, Inc.
41
Table 16. At-A-Glance Specifications
Hardware
Description
Specification
Transmitter
Output Power
+20 dBm, maximum
Frequency Range
5725 to 5850 MHz
Receiver
Receive Level,
Minimum
-85 dBm @ 8xT1
-89 dBm @ 4xT1
-92 dBm @ 2xT1
-83 dBm @ 8xE1/16Mbps Ethernet
-87 dBm @ 4xE1/8 Mbps Ethernet
-90 dBm @ 2xE1/4 Mbps Ethernet
Receive Level, Maximum
-30 dBm
Receive Level, Nominal
-55 dBm
Intermediate Frequencies (IF)
IDU to ODU
280 MHz
ODU to IDU
140 MHz
Frequency Plan
Plan A
Band Plan
1
Tx 5.744 GHz, Rx 5.824 GHz
2
Tx 5.747 GHz, Rx 5.827 GHz
3
Tx 5.751 GHz, Rx 5.831 GHz
Plan B
Band Plan
1
Tx 5.824 GHz, Rx 5.744 GHz
2
Tx 5.827 GHz, Rx 5.747 GHz
3
Tx 5.831 GHz, Rx 5.751 GHz
Data Encryption
Encryption Type
Symmetric Triple-DES (3DES)
User Interface
Panel
Alarm LEDs
Diagnostics
RF link diagnostics and error history, transmit and
receive packets history
Test Points
RSSI and Ground (GND)
Alarms
Normally Open (NO) and Normally Closed (NC)
User Interface
VT100 Terminal
Menu driven user interface, control of the remote end,
event history
Telnet Access
Menu driven user interface, control of the remote end,
event history
SNMP
Standard MIB support (T1/E1 and Ether-like MIBs);
Enterprise MIB support (ADTRAN TRACER MIB)