TRACER 6000 Series Split System Manual
Section 5 User Interface Guide
612806320L1-1B
63
> S
YSTEM
C
ONFIGURATION
> S
YSTEM
D
ATE
Displays the current date. To edit this field, place the cursor on the field and press
<Enter>
. Then, enter
the date in mm-dd-yyyy format (for example, 10-30-1998). Press
<Enter>
when you are finished to accept
the change.
> S
YSTEM
C
ONFIGURATION
> E
LAPSED
T
IME
Displays the length of time the TRACER system has been running. Each time you reset the system, this
value resets to 0 days, 0 hours, 0 min, and 0 secs.
> S
YSTEM
C
ONFIGURATION
> CRAFT P
ORT
B
AUD
Specifies the baud rate of the port. Select either
9600
(default),
19200
,
38400
,
57600
, or
115200
bps. If
you are using the
CRAFT
port for modem access, ensure that the
CRAFT
port rate matches the modem
baud rate.
> S
YSTEM
C
ONFIGURATION
> I
NACTIVITY
L
OGOUT
This option defines the amount of time in minutes the user can stay connected without any activity on the
CRAFT
port before the user is automatically logged out of the system. Select one of the following:
5
MIN
,
10
MIN
(default),
15
MIN
,
30
MIN
,
45
MIN
,
60
MIN
, or
O
FF
.
> S
YSTEM
C
ONFIGURATION
> P
ASSWORD
Sets the password for password protection of the TRACER terminal interface. Enter up to eight
alphanumeric characters. The system password is case sensitive.
> S
YSTEM
C
ONFIGURATION
> P
ERFORMANCE
S
TATS
(C
LEAR
)
Resets all system error counters for the TRACER.
> S
YSTEM
C
ONFIGURATION
> F
ACTORY
D
EFAULTS
Resets the system to the factory default settings. The configured
IP A
DDRESS
,
S
UBNET
M
ASK
, and
D
EFAULT
G
ATEWAY
are not defaulted during a factory default. When you select this command, the following
confirmation message appears:
Are you sure you want to restore factory Defaults? Y or N
Press
Y
to restore factory defaults or
N
to cancel this command.
Changes to the
I
NACTIVITY
L
OGOUT
setting do not apply to the current session. All changes
take affect at the next login to the system menus.
The default password for the TRACER is password.
The
T
OTAL
A
CTIVE
C
HANNELS
parameter (on the Datapath Provisioning menu page) is
reset to the factory default value (
8
). Performing a factory default on any system with less
than eight active channels results in an RF link loss.