Chapter 4. Using the Front Panel
61200226L1-1
ATLAS 800
PLUS
User Manual
4-9
» S1—S8
Displays the current configuration options of installed modules.
S1
corre-
sponds to slot 1,
S2
to slot 2, and so on. When you select one of these options,
you can enable or disable the selected module. The current status,
ENA
(En-
abled) or
DIS
(Disabled), displays next to the module name. Set this field to
DIS
(Disable) prior to removing a module from the ATLAS 800
PLUS
unit.
>
UTIL
The
Utility
menu allows miscellaneous settings to be displayed or modified.
» Time/Date
Displays and/or edits the current time and date. The ATLAS 800
PLUS
main-
tains the time and date during power off conditions.
After any numeric change, press
Enter
to record the entry and move to the
next editing position. You can also move to a different field to edit by press-
ing
Enter
at the editing position without making any change, or by using the
up
and
down arrow
keys
. Press
Cancel
at any time to end the editing pro-
cess.
» Software Rev
Displays the current software revision level loaded into the Base Unit con-
troller. This information is required when requesting assistance from ADT-
RAN Technical Support or when updates are needed. Press
Cancel
to exit
this option.
Unit ID
Accesses the current Unit ID setting, which is the system
identifier used for ADTRAN Data Link Layer Protocol
(ADLP) configuration control (such as using T-Watch
PRO).
Editing or changing the Unit ID requires the use of a
passcode if a passcode is defined. See Set Passcode on
page 4-11 for details on working with passcodes. Unit
Identification numbers must be between 2 and 9999. The
number 1 is reserved for the PC.
Press
Enter
to record the Unit ID number and establish
its availability when operating by remote control. Press
Cancel
at any time to end the editing process.
Init Modem
Provides the option to send the modem initialization
string (e.g., ATE0V1&D2S0=1) from the chain port to a
modem connected to the chain port. Configure this
string in the terminal menus. See Modem Initialization
String on page 6-9 for details on how to change this field.
The
Init Modem
option is only used if
Type
is set to
Dial.
Summary of Contents for Atlas 800 Plus
Page 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Page 12: ...xii...
Page 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Page 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Page 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Page 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Page 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Page 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Page 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Page 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Page 210: ......