Chapter 9. Dedicated Circuit Backup and Circuit Status
9-4
ATLAS 800
PLUS
User Manual
61200226L1-1
» Restore Delay
This only applies to originating endpoints. The amount of time to delay after
clearing an alarm before coming out of backup. If the circuit goes into alarm
before this time has expired, the endpoint will remain in backup.
» Max Num Redials
This only applies to originating endpoints. The backup endpoint will at-
tempt this many retries before giving up and declaring a backup failure.
» Redial Timer
This only applies to originating endpoints. The amount of time delayed be-
tween a failed backup call and the redial.
» Enable Schedule
Use this menu to schedule the times when backup is enabled. The following
selections are available for the
Enable Schedule
menu item.
» Test Call
This only applies to originating endpoints. Use this menu to schedule regu-
larly occuring test calls. The following selections are available for the
Test
Call
menu item.
» Min Num DS0s
This option will specify the number of DS0s to use for this switched call. If
this number is 1, all calls will be directly to the endpoint, and not use a
BONDING resource. Any number other than 1 will use BONDING resourc-
es to inverse multiplex the multiple switched channels together.
» Max Num DS0s
This option will specify the number of DS0s to use for this switched call. If
this number is 1, all calls will be directly to the endpoint, and not use a
BONDING resource. Any number other than 1 will use BONDING resourc-
es to inverse multiplex the multiple switched channels together.
Enable Time
This is the time of day to enable dial backup.
Disable Time
This is the time of day to disable dial backup. If the dis-
able time is earlier than the enable time, backup moni-
toring will be active across midnight.
Days Enabled
Use this record to enable/disable backup monitoring
on particular days of the week.
Period
How often test calls are to be made.
Next Test Time
The date of the next scheduled test call.
Summary of Contents for Atlas 800 Plus
Page 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Page 12: ...xii...
Page 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Page 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Page 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Page 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Page 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Page 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Page 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Page 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Page 210: ......