Chapter 2. Installing the ATLAS 800PLUS
2-2
ATLAS 800
PLUS
User Manual
61200226L1-1
AC Powered Unit
The AC powered ATLAS 800
PLUS
(P/N 1200226L1) comes equipped with a
detachable 8-foot power cord with a three-prong plug for connecting to a
grounded power receptacle.
DC Powered Unit
The DC powered ATLAS 800
PLUS
(P/N 1200228L1) comes equipped with a
terminal block on the rear of the unit. The power source should be connected
to the terminal block according to the polarity markings on the unit. For ex-
ample, a -48 V source would be connected with the -48V return connected to
the (+) terminal and the -48VDC attached to the (-) terminal. Power must be
from a DC power source in the range of 42 to 57 VDC, capable of delivering
up to 7 A of current.
The
GROUNDING INSTRUCTIONS
This section provides grounding instruction information from the Under-
writers' Laboratory UL 1459 Standard for Safety: Telephone Equipment, of
September 20, 1993.
An equipment grounding conductor that is not smaller in size than the un-
grounded branch-circuit supply conductors is to be installed as part of the
circuit that supplies the product or system. Bare, covered, or insulated
grounding conductors are acceptable. Individually covered or insulated
equipment grounding conductors shall have a continuous outer finish that
is either green, or green with one or more yellow stripes. The equipment
grounding conductor is to be connected to ground at the service equipment.
The attachment-plug receptacles in the vicinity of the product or system are
all to be of a grounding type, and the equipment grounding conductors serv-
ing these receptacles are to be connected to earth ground at the service
equipment.
A supplementary equipment grounding conductor shall be installed be-
tween the product or system and ground that is in addition to the equipment
grounding conductor in the power supply cord.
Power to the ATLAS 800
PLUS
must be from a grounded 115 VAC,
60 Hz or 220 VAC, 50-60 Hz source.
The branch circuit overcurrent protection shall be a fuse or circuit
breaker rated minimum 48 V, maximum 20A.
A readily accessible disconnect device that is suitably approved and
rated shall be incorporated into the fixed wiring.
Summary of Contents for Atlas 800 Plus
Page 1: ...ATLAS 800PLUS User Manual Part Number 1200226L1 Part Number 1200228L1 61200226L1 1C May 2000...
Page 12: ...xii...
Page 26: ...List of Tables xxvi ATLAS 800PLUS User Manual 61200226L1 1...
Page 34: ...Chapter 1 Introducing the ATLAS 800PLUS 1 8 ATLAS 800PLUS User Manual 61200226L1 1...
Page 48: ...Chapter 3 Operating the ATLAS 800PLUS 3 6 ATLAS 800PLUS User Manual 61200226L1 1...
Page 66: ...Chapter 5 Navigating the Terminal Menu 5 6 ATLAS 800PLUS User Manual 61200226L1 1...
Page 94: ...Chapter 7 Modules Terminal Menu 7 8 ATLAS 800PLUS User Manual 61200226L1 1...
Page 180: ...Appendix A System Event Logging A 14 ATLAS 800PLUS User Manual 61200226L1 1...
Page 184: ...Appendix B Troubleshooting B 4 ATLAS 800PLUS User Manual 61200226L1 1...
Page 208: ...Index Index 14 ATLAS 800PLUS User Manual 61200226L1 1...
Page 210: ......