Fire Alarm System Operation
Introduction to Fire Alarm System Operation
Your fire alarm system (if installed) is on 24 hours a day, providing continuous
protection. In the event of an emergency, the installed smoke and heat detectors
will automatically send signals to your Control/Communicator, triggering a loud
interrupting sound from the touchpad. An interrupted sound will also be produced
by optional exterior sounders. A FIRE message will appear at your touchpad and
remain on until you silence the alarm.
In Case of Fire Alarm
1. Should you become aware of a fire emergency before your detectors sense the
problem, go to your nearest touchpad and manually initiate an alarm by
pressing the panic key assigned as FIRE emergency (if programmed by the
installer) and hold down for at least 2 seconds.
2. Evacuate all occupants from the premises.
3. If flames and/or smoke are present, leave the premises and notify your local Fire
Department immediately.
If no flames or smoke are apparent, investigate the cause of the alarm. The zone
descriptor of the zone(s) in an alarm condition will appear at the touchpad.
Silencing a Fire Alarm
1. Silence the alarm by entering your code and pressing the OFF key. To clear the
display, enter your code and press the OFF key again
2. If the touchpad does not indicate a READY condition after the second OFF
sequence, press the READY key to display the zone(s) that are faulted. Be sure
to check that smoke detectors are not responding to smoke or heat producing
objects in their vicinity. In this case, eliminate the source of heat or smoke.
3. If this does not remedy the problem, there may still be smoke in the detector.
Clear it by fanning the detector for about 30 seconds.
4. When the problem has been corrected, clear the display by entering your code
and pressing the OFF key.
Fire Display Lock
If several zones produce an alarm before any are silenced, the system can be
programmed to lock the touchpad display with the first zone that produced an
alarm. Ask your installer if your system has been activated with this feature. To
display the other zone(s), press the [
✴
] key for each zone. Also the “A”, “B”, or “C”
keys can be programmed to scroll the touchpad display to view the previous or
subsequent fire alarms.
Summary of Contents for iCenter 8142ADT
Page 2: ......
Page 8: ...Table of Contents Cont d 8...
Page 30: ...Security System Operation cont d 30...
Page 44: ...User Code Setup cont d 44...
Page 86: ...TeleSMART Messaging Features cont d 86...
Page 102: ...Advanced System Features Cont d 102 ACTION SCREEN 4 Enter 1 YES or 0 NO Press to continue...
Page 104: ...Testing the System Cont d 104...
Page 126: ...Maintaining Your System cont d 126...
Page 136: ...ADT Security Services Inc One Town Center Rd Boca Raton FL 33486 Copyright 2000 l K5763 1 1 01...