iFT Series Hardware Installation Manual
ADPRO
74
27817_08
22. Re-insert the SATA cable to connect the DOM to the motherboard.
23. Re-insert the DOM’s power cable.
24. Put the cover back in place and switch on the power supply. The XO device restarts.
25. Reconnect the XO client to the XO device using the default IP address (10.0.0.10) and the
username/password of a default user.
20.2
After a Full Reset
After a full reset, the system contains no more licenses. The system license is no longer available either. An XO
device running without system license will inform the user of the license error via the event message 0013 –
[SYST] – SYSTEM LICENSE ERROR, and via a popup window at each connection with the XO client. You have
to restore the system license immediately to have access to full functionality.
You can restore your system license via the
Transfer
function in the XO client. In some cases, you can also try
to restore the system license using Xchange. For details, see the
Xchange Tool User Manual
(27816).
You can restore:
l
the system license: via the XO client from the backup that you made before resetting, or via Xchange (if
available).
l
the application licenses: via Xchange.
l
other files (configurations, calibration pictures…): via the XO client from the backup that you made before
resetting.
You will need to reconfigure the MIO card and Net I/O units manually.