ADPRO
iFT Series Hardware Installation Manual
27817_08
13
The screen displays the following information:
Item
Description
Device
Device name of the hard disk (Linux).
Power status
The power status column displays one of the following statuses:
l
ERROR
: there is a problem retrieving the power status of the drive
l
ACTIVE/IDLE
: drive operates normally
l
STANDBY
: drive is in low power mode (drive is in spin-down status)
l
SLEEPING
: drive is in lowest power mode (drive is completely shut down).
Smart status
The smart status column displays one of the following statutes:
l
ERROR
: drive is failing
l
ALERT
: there is a problem retrieving SMART info from the drive, or the drive may be
in the process of failing
l
NORMAL
: no problems found with the drive.
Temperature
The temperature column displays from left to right:
l
the minimum temperature of the disk
l
the current temperature of the disk
l
the maximum temperature of the disk.
Force
l
ON
: SMART is checked on disk in STANDBY or SLEEPING mode.
l
OFF
: SMART is only checked on disks in ACTIVE/IDLE mode.
Interval
Indicates the interval (in minutes) between SMART checks.
Temperature
threshold
If the disk temperature is higher than the temperature threshold, the system activates
system input 0102 – [SYST] – SMART HDD ALERT TEMP.
3.4.2
Using the XO Client Software
To obtain to obtain the (SMART) information for all hard disks in the XO device in the XO client, choose
System
>
Maintenance
>
Harddisks
. The
Smart
column shows the operational status of the hard disks; the
Temp
column indicates the temperature.
3.5
Installing the First Hard Disk
Note
If you need to install 2 or more hard disks, follow the instructions in
page 16 instead.
Material required for the first hard disk:
Part
reference number
Disk screws
4 x #17434080
SATA cable
1 x #16520877