3 4
SECTION 17
Pilot flame shrinks when fire is on high
Poor gas flow to fire - Check pressure with fire on high.
If pressure is low - Remove any restriction in pipe work or valve.
Check all isolators are adequately sized and fully open.
Check meter pressure is adequate.
Air leak under base of firebox - Rectify.
Lint in pilot aeration hole - Clean thoroughly internally.
Firebox grommet seal missing - Rectify
Fire smells when first lit or in use
Newness smell from brand new appliance.
Spillage occurring - Call installer to carry out spillage test and
rectify any problems.
Low temperature sealants or combustible materials used in
incorrect
positions.
Air leak under base of firebox - Rectify
Firebox grommet seal missing rectify.
Remote control
Remote Control Diagnostic "Beeps" (Do not mix battery types)
3 "beeps"
Replace handset or dummy switch
4 "beeps"
Replace Gas Valve
5 "beeps"
Replace EDB control box
6 "beeps"
Battery below required power . Replace all batteries in the
appliance
7 "beeps"
Battery below required power. Replace all batteries in the
appliance
Do Not use ZINC batteries
Battery life tests show that Duracell batteries discharge at higher rates when exposed to
heat despite their reputation for longer life Ever ready Energiser industrial are regarded
as one of the best available.
To get back to a stable reference condition, remove the battery pack and wait 10
minutes for the internal capacitor to discharge. Reconnect the battery pack and carry
out an ignition attempt, short cutting this procedure can give a false indictor.
Summary of Contents for Eco4
Page 42: ...4 2 S E C T I O N 1 9 LIST OF SPARES Eco4 Manual Control ...
Page 43: ...4 3 S E C T I O N 1 9 Eco4 Slide Control ...
Page 44: ...4 4 S E C T I O N 1 9 Eco4 Remote Control 1C 2C 4C 5C 3C 6C ...
Page 45: ...4 5 S E C T I O N 1 9 Eco4 Ceramics ...
Page 46: ...4 2 4 6 S E C T I O N 1 9 Eco4 Ceramics A22 A23 ...