2 8
SECTION 10
SPARK FAILURE
The gap between the spark electrode and the pilot should be 3.5 - 4.5mm to produce
a good spark. There should be no need to adjust this.
If under any circumstances the electric spark fails, the pilot may be lit manually by
proceeding with the ignition sequence as previously described, and after turning the
control knob through the spark position, the knob should be held in and the pilot lit with
a taper.
Note: Please ensure that the electrode spark igniters’ gap on the manual version has
not been misaligned during the handling of the burner. In this installation the gap
should be 5mm from the burner.
SETTING PRESSURE
Remove the pressure test point sealing screw from the isolation elbow and attach a
suitable pressure gauge.
Check that the standing inlet gas pressure is at 20 mbar
Light the pilot and check the correct operation of the burner at all the flame settings.
Refer to the Operating instructions section 10.1
Check that the inlet gas pressure is at 20 mbar when the fire is at its highest setting.
SECTION 11