SECTION 05
Eco 4
A
Height
552-575mm
B Width
350-455mm
C
Depth
113mm
Hotbox
/
134mm
Convector
D
Minimum hearth depth in front of the fire
300mm
E
Hearth must extend minimum of
150mm
F Minimum
hearth
height
50mm
HOLE-IN-THE-WALL INSTALLATIONS
Where the appliance is to be installed as a hole-in-the-wall fireplace, a hearth as
previously detailed for floor level fireplaces shall be fitted on the floor beneath the hole
so as to protect combustible material from heat.
However, if a hearth is not to be used, so as to maintain a minimal and contemporary
look, the appliance must be installed so that every part of any naked flame
or incandescent part of the fire bed is at least 300mm vertically above any
carpet or floor covering.
When no hearth is to be fitted consideration must be given to fixing a
tactile barrier to protect young children, the elderly and the infirm.
A tactile barrier can be in the form of a fender, kerb, hearth, shelf or
horizontal bar all made from non combustible material and fixed not less
than 50mm & not more than 1000mm above the floor level. They should be
Positioned not less than 300mm in front of the appliance.
E
C
D
A
B
F