WARNING

This conversion kit shall be installed by 

a qualified service agency in accordance 

with the manufacturer’s instructions and 

all applicable codes and requirements 

of the authority having jurisdiction. If 

the information in these instructions is 

not followed exactly, a fire, explosion 

or productions of carbon monoxide 

may result, causing property damage, 

personal injury, or loss of life. The 

qualified service agency is responsible 

for proper installation of this kit. The 

installation is not proper and complete 

until operation of the converted 

appliance is checked as specified in the 

manufacturer’s instructions supplied 

with the kit. Refer to appliance owner’s 

manual or product data plate for proper 

inlet and manifold pressure adjustments 

and orifice sizing.

IMPORTANT

THE CONVERSION SHALL BE CARRIED OUT BY A 

MANUFACTURER’S AUTHORIZED REPRESENTATIVE, 

IN ACCORDANCE WITH THE REQUIREMENTS 

OF THE MANUFACTURER, PROVINCIAL OR 

TERRITORIAL AUTHORITIES HAVING JURISDICTION 

AND IN ACCORDANCE WITH THE REQUIREMENTS 

OF THE CAN/CGA-B149.1 OR CAN/CGA-B149.2 

INSTALLATION CODES.

CETTE CONVERSION DE GAZ DOIT ÊTRE EFFECTUÉE 

PAR UN REPRÉSENTANT AUTORISÉ DU FABRICANT, 

CONFORMÉMENT AUX EXIGENCES DU FABRICANT ET 

DES AUTORITÉS PROVINCIALES OU TERRITORIALES 

AYANT JURIDICTION, ET AUX EXIGENCES DES 

CODES D’INSTALLATION CAN/CGA-B149.1 OU CAN/

CGA-B149.2.

READ ALL STEPS BEFORE STARTING INSTALLATION.  

LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.

This gas conversion kit installation instructions must be used in 
conjunction with the installation and operation manual provided with 
the appliance. Please read the appliance owner’s manual completely 
before performing any procedures in these instructions. All warnings, 
precautions, and instructions outlined in the manual provided with the 

appliance will continue to apply to these instructions. 

AVERTISSEMENT

Ce kit de conversion doit être installé 

par une agence d’entretien qualifiée, 

selon les instructions du fabricant et 

tous codes et règlements applicables 

de l’autorité ayant juridiction. Le non-

respect de ces instructions peut créer un 

incendie, une explosion ou la production 

de monoxyde de carbone, et causer des 

dommages matériels, des blessures 

ou même la mort. L’agence d’entretien 

qualifiée est responsable de la qualité 

d’installation de ce kit. L’installation 

ne sera conforme et complète qu’après 

avoir vérifié le fonctionnement du 

foyer converti, tel que spécifié dans les 

instructions du propriétaire fournies 

avec ce kit. Voir le manuel d’utilisation 

ou la plaque signalétique de l’appareil, 

pour les réglages de pressions d’entrée 

et du manifold et les dimensions d’orifice 

(injecteur) de brûleur/veilleuse.

Hussong Manufacturing Co., Inc.
204 Industrial Park Drive, PO Box 577
Lakefield, MN 56150-0577, USA

SFD-36 • Rev. 1, 2/22

Report Number: 19-555

Starting Serial Number: 

22 405450 10

This fireplace is certified under U.S. and Canadian standards ANSI Z21.88-2017/CSA 2.33-2017, CSA 2.17-2017

#LCK-SF36-D

HUSSONG MANUFACTURING CO., INC.

PROPANE CONVERSION KIT

For model Springfield 36

Direct Vent Gas Fireplace

Summary of Contents for LCK-SF36-D

Page 1: ... APPLIANCE This gas conversion kit installation instructions must be used in conjunction with the installation and operation manual provided with the appliance Please read the appliance owner s manual completely before performing any procedures in these instructions All warnings precautions and instructions outlined in the manual provided with the appliance will continue to apply to these instruct...

Page 2: ......

Page 3: ...he burner assembly and burner heat shield Refer to the installation manual for more information B Replace Burner Orifice Step 1 Remove the existing burner orifice See FIGURE 1 Step 2 Replace with the orifice cap included with this kit Tighten cap securely The size are stamped on the orifices Table 1 Burner Orifice Size at Elevations 0 4 500 1 372m Fuel Orifice Size Propane 1 75mm DMS C Convert Pil...

Page 4: ...e screw securing the venturi cap and adjust to the correct setting See FIGURE 5 and TABLE 2 Regardless of venturi orientation closing the air shutter will achieve a desired yellow flame but may produce soot on the glass Opening the air shutter will cause a short blue flame that may lift off the burner Slight adjustments to the venturi opening will create dramatic results Adjust at slight increment...

Page 5: ...rew clockwise The screw should be snug do not over tighten Step 6 Relight the pilot and burner Step 7 Reattach the manometer to the outlet pressure tap to verify tap is completely sealed Manometer should read no pressure Table 4 Manifold Gas Supply Pressures Fuel Low High Propane 2 7 WC 0 67 kPa 10 WC 2 49 kPa H Verify Operation Step 1 Light the pilot Visually check the pilot flame to verify flame...

Page 6: ...r plus d information consulter le manuel d installation B Remplacement l orifice du brûleur Étape 1 Retirez l orifice du brûleur existant Voir FIGURE 1 Étape 2 Remplacez le par le nouvel orifice de brûleur fourni avec le kit numéro marqué sur l orifice du brûleur en veillant à bien serrer l orifice du brûleur Tableau 1 Taille de orifice du brûleur aux altitudes 0 4500 pi 1372 m Combustible Taille ...

Page 7: ...tenant obturateur d air du venturi et ajustez le au réglage approprié Voir FIGURE 5 et TABLEAU 2 Réduire l ouverture de l obturateur d air du venturi avant ou arrière donnera la couleur de flamme jaune désirée mais cela peut encrasser la vitre suie Un venturi plus ouvert produira une flamme bleue plus courte qui peut sautiller du brûleur De légers ajustements d ouverture du venturi produiront un e...

Page 8: ... vis du raccord de test de pression de sortie sens horaire La vis doit être vissée juste assez ne la serrez pas trop Étape 6 Rallumez la veilleuse et le brûleur Étape 7 Rebranchez le manomètre au raccord de test de pression de sortie manifold pour vérifier que ce raccord est bien étanche Le manomètre ne devrait indiquer aucune pression Tableau 4 Pressions d alimentation de gaz au manifold Combusti...