Page 1: ... APPLIANCE This gas conversion kit installation instructions must be used in conjunction with the installation and operation manual provided with the appliance Please read the appliance owner s manual completely before performing any procedures in these instructions All warnings precautions and instructions outlined in the manual provided with the appliance will continue to apply to these instruct...

Page 2: ......

Page 3: ...he burner assembly and burner heat shield Refer to the installation manual for more information B Replace Burner Orifice Step 1 Remove the existing burner orifice See FIGURE 1 Step 2 Replace with the orifice cap included with this kit Tighten cap securely The size are stamped on the orifices Table 1 Burner Orifice Size at Elevations 0 4 500 1 372m Fuel Orifice Size Propane 1 75mm DMS C Convert Pil...

Page 4: ...e screw securing the venturi cap and adjust to the correct setting See FIGURE 5 and TABLE 2 Regardless of venturi orientation closing the air shutter will achieve a desired yellow flame but may produce soot on the glass Opening the air shutter will cause a short blue flame that may lift off the burner Slight adjustments to the venturi opening will create dramatic results Adjust at slight increment...

Page 5: ...rew clockwise The screw should be snug do not over tighten Step 6 Relight the pilot and burner Step 7 Reattach the manometer to the outlet pressure tap to verify tap is completely sealed Manometer should read no pressure Table 4 Manifold Gas Supply Pressures Fuel Low High Propane 2 7 WC 0 67 kPa 10 WC 2 49 kPa H Verify Operation Step 1 Light the pilot Visually check the pilot flame to verify flame...

Page 6: ...r plus d information consulter le manuel d installation B Remplacement l orifice du brûleur Étape 1 Retirez l orifice du brûleur existant Voir FIGURE 1 Étape 2 Remplacez le par le nouvel orifice de brûleur fourni avec le kit numéro marqué sur l orifice du brûleur en veillant à bien serrer l orifice du brûleur Tableau 1 Taille de orifice du brûleur aux altitudes 0 4500 pi 1372 m Combustible Taille ...

Page 7: ...tenant obturateur d air du venturi et ajustez le au réglage approprié Voir FIGURE 5 et TABLEAU 2 Réduire l ouverture de l obturateur d air du venturi avant ou arrière donnera la couleur de flamme jaune désirée mais cela peut encrasser la vitre suie Un venturi plus ouvert produira une flamme bleue plus courte qui peut sautiller du brûleur De légers ajustements d ouverture du venturi produiront un e...

Page 8: ... vis du raccord de test de pression de sortie sens horaire La vis doit être vissée juste assez ne la serrez pas trop Étape 6 Rallumez la veilleuse et le brûleur Étape 7 Rebranchez le manomètre au raccord de test de pression de sortie manifold pour vérifier que ce raccord est bien étanche Le manomètre ne devrait indiquer aucune pression Tableau 4 Pressions d alimentation de gaz au manifold Combusti...