1 9
SECTION 7.1
Push the appliance back into the fireplace, centralise and pull the loose cables
through the hole into the firebox.
Thread the cable tensioner onto the cable as shown, with the nuts screwed down
close to the tensioner head.
Slide the screwed nipple through the box and pull cable taut and tighten pinch screw
on to the cable.
Adjust tensioner using a suitable spanner to pull the cable tight into position, to allow
an even seal around the edge of the fire, visually inspect the seal and reseat if
necessary.
Fixing by screw:
Mark and drill the fire frame or base, and relevant points in the opening or on the wall.
wall plugs will be required.
Note: Fibre wall plugs might be preferred rather than plastic wall plugs as the heat from
the fire might affect their efficiency.
Whilst the opening is ready for installation of the fire, the gas supply can be routed as
required and connected to the isolation tap via the 8mm compression fitting.
Note: In no circumstance should you use soft soldered connections to or underneath
the burner tray.
Pinch screw
Tension nut
Surplus tension cable MUST NOT be cut off as this will
prevent proper installation after servicing simply coil up
the surplus cable as shown and tuck the coils out of
the way.
Summary of Contents for Eco4
Page 42: ...4 2 S E C T I O N 1 9 LIST OF SPARES Eco4 Manual Control ...
Page 43: ...4 3 S E C T I O N 1 9 Eco4 Slide Control ...
Page 44: ...4 4 S E C T I O N 1 9 Eco4 Remote Control 1C 2C 4C 5C 3C 6C ...
Page 45: ...4 5 S E C T I O N 1 9 Eco4 Ceramics ...
Page 46: ...4 2 4 6 S E C T I O N 1 9 Eco4 Ceramics A22 A23 ...