47
Maintenance and cleaning
Warning indicator
The WARNING indicator shows the state of the function which protects the projector. Check the state of the WARNING
indicator and the POWER indicator to take proper maintenance.
The projector is shut down and the WARNING indicator
is blinking red.
When the temperature inside the projector exceeds the normal
temperature, the projector is automatically shut down to protect
internal components. The POWER indicator is blinking while the
projector is being cooled down. When the projector has cooled
down enough (to its normal operating temperature), it can be
turned on again by pressing the STAND-BY button.
Top control
Warning
indicator
Blinking red
√
Note:
The WARNING indicator continues to blink even after the
temperature inside the projector returns to normal. When the
projector is turned on again, the WARNING indicator stops
blinking.
Check the items below:
– Did you provide appropriate space for the projector to be ventilated?
Check the installing condition to see if ventilation slots are not blocked.
– Has the projector been installed near the duct or vent of an air-
conditioning? Move the installation of the projector away from the duct
or vent.
– Are the air filters clean? Clean the air filters periodically.
The projector is shut down and the WARNING
indicator lights red.
Top control
When the projector detects an abnormal condition, it is
automatically shut down to protect the internal components
and the WARNING indicator lights red. In this case, unplug
the AC power cord and plug it, and then turn on the projector
once again to verify operation. If the projector cannot be
turned on and the WARNING indicator lights red, unplug the
AC power cord and contact the service station for servicing
and maintenance.
Warning
indicator lights
red
Caution Do not leave the projector with the AC power
cord connected under an abnormal condition. It may
result in fire or electric shock.
⑨ ⑩ ⑪
⑨ ⑩ ⑪