7
PIPE CONNECTIONS
(CUT)
Fig. 1
PIPE CONNECTIONS
(
FLARING
)
Fig. 3
PIPE CONNECTIONS
(B
URR
REMOVAL)
Fig. 2
PIPE CONNECTIONS
(FI
)
Fig. 4
3.
OUTDOOR UNIT INSTALLATION
3.1 GENERAL INDICATIONS
When choosing the installation position, respect carefully the
following indications:
Fig. 5
-
Make sure that the difference between the INTERNAL UNIT
and the UNIT
OUTSIDE is not greater than 5.0 m.
- The appliance must be installed so that the influences
of
adjacent structures and / or the effects of climatic conditions
details (snow, wind, etc. ...) do not compromise the
product
operation and / or personal safety e
of assets.
- Make sure that the space at the back of the unit is
greater than
30 cm. The front must have more than 60
cm. of space.
- Ensure that there are no obstacles to free movement
of air
through heat exchangers: A) do not dispose
plants or animals
directly close to the air flow;
B) avoid installation in corners where it is usually deposited
dust, leaves and anything else that can reduce efficiency
of the exchangers obstructing the passage of air (Fig 5).
- Position the air discharge so that the flow is not
hampered in
any way. In the case of strong winds, make sure
the fan works
correctly, positioning the unit
longitudinally, along a wall or using
one
shielding