25
Nominal power
Equipment category
Minimum pressure of the heating circuit
Maximum pressure of the heating circuit
Minimum DHW circuit pressure
Maximum pressure of the sanitary circuit
Domestic hot water flow rate
Power supply - Voltage / Frequency
Fuse on the power supply
Maximum absorbed power
Degree of electrical protection
Net weight
Methane gas consumption at maximum heating capacity
LPG consumption at maximum heating capacity
Fan speed G20 heating max / min.
Sanitary fan speed G20 max
LPG fan speed max / min heating (X100)
Max LPG sanitary fan speed (x100)
Fan speed G20 starting (x100)
LPG fan speed (x100)
T
Max operating temperature in heating mode
Total expansion vessel capacity
6.5 TECHNICAL FEATURES BOILER HUB RADIATOR PACK CF
TECHNICAL FEATURES
kW
bar
bar
bar
bar
l/min
V - Hz
A
W
IP
Kg
m
3
/h
m
3
/h
rpm
rpm
rpm
rpm
rpm
rpm
°C
l
24
II2H3P
0,5
3
0,5
6
11
230 - 50
3,15
87
X4D
29,9
2,54
0,75
48/9
62,5
54/9
64,5
35
32
85
9
Losses with burner off
Chimney leaks with working burner
Smoke mass flow rate
T
Smoke temperature
Useful thermal efficiency at maximum power
(60/80 °C)
Useful thermal efficiency at maximum power
(30/50 °C)
Useful thermal efficiency at maximum power
(60/80 °C)
Useful thermal efficiency at maximum power
(30/50 °C)
Useful thermal efficiency at 30% of the load
NOx emission class
Technical data table
%
%
g/s
°C
%
%
%
%
%
P. max
0,3
3,7
9,9
70
95,8
103,4
-
-
-
P. min
2,4
1,8
1,3
62
-
-
90,0
102,1
-
6
Carico 30%
-
-
-
-
-
-
-
-
107,1
Summary of Contents for HUB RADIATOR PACK CF 3.0