xFUME POWER 250
4 Product description
EN
-
13
4.2.1 Control box
Fig. 3
Control box
A
Welding voltage display
Display for welding voltage in volts. Indicates the present welding
voltage.
B
Welding current/wire feed speed
display
Display for the current in amperes. Indicates the present current
intensity. If the device is in stand-by mode, the wire feed speed is
displayed in %.
C
Control dial for welding choke
Changes the arc (soft/hard) when rotated.
Low value: low choke effect = hard arc.
High value: high choke effect = soft arc.
D
Service LED
The LED flashes when the filter is full/clogged. The device stops the
welding process. Following the filter change, the LED goes out after
5 seconds and the welding process can be restarted.
E
Control dial for wire feed speed
The wire feed speed can be adjusted steplessly by rotating the control
dial.
F
Toggle switch for mode
Centre position: the device is ready for standard welding.
Left position: gas test.
Right position: wire feed speed test.
G
Control dial for welding voltage
Stepless adjustment of the welding voltage during the welding
process.
H
Power LED
The power LED continually lights up green if there is no fault. If there
is a fault, the power LED goes out.
F
E
G
H
A
B
C
D