EN
-
10
2 Safety
xFUME
®
POWER 250
2.5 Product-specific safety instructions
2.6 Safety instructions for the power supply
► Ensure that the power supply cable does not become damaged, e.g. by being driven over, crushed or
torn.
► Inspect the power supply cable at regular intervals for damage or wear.
► If the power supply cable requires replacement, only versions indicated by the manufacturer must be
used.
► The 400 V 50 Hz/60 Hz mains connector must be protected by a 32 A fuse.
► Only a qualified electrician should replace the power supply cable and the mains plug.
► Ensure splash-water protection and mechanical stability when replacing the mains plug and power
supply cable.
► To replace or lengthen the power supply cable, always use an H07RN-F5G6 rubberized
cable (400 V).
WARNING
Danger of fire and explosion due to improper use
The extraction of flammable, aggressive chemical or oil-laden substances and materials as well as dusts
containing aluminum or magnesium can pose a risk of fire and explosion due to chemical reactions. This
could cause major burns.
► Use the device according to its designated use only.
WARNING
Health risk caused by inhaling harmful dust
The device contains harmful dust as of the first use. This can damage the respiratory tract if inhaled.
► Check and wear your personal protective equipment.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Keep the device closed during operation and during the cleaning process.
► Only use the device in rooms with sufficient ventilation.