EN
-
32
10 Faults and troubleshooting
xFUME
®
POWER 250
10 Faults and troubleshooting
► Consult the documentation for the welding components.
► If you have any questions or problems, consult an appropriate specialist dealer or ABICOR BINZEL.
WARNING
Health risk caused by inhaling harmful dust
The device contains harmful dust that can collect on surfaces and penetrate the ambient air as of the first
use. This can damage the respiratory tract when inhaled.
► Check and wear your personal protective equipment.
► Only use the device in rooms with sufficient ventilation.
► The provided filtration system must be used when operating the device.
► The dust collecting drawer must be closed when operating the device.
► Do not open the dust collecting drawer for at least one minute after the device is switched off.
► Immediately remove dust deposits from the environment with a dust class H industrial vacuum cleaner
or a damp cloth.
Tab. 9
Faults and troubleshooting
Fault
Cause
Troubleshooting
System switches off,
welding stops.
System overheats if in use for too
long and if the ambient
temperature is too high.
Service LED
is illuminated.
► Let the system cool and restart the
welding process.
No function when torch
button is pressed.
Welding torch button is defective. ► Repair the button.
See the operating instructions
for the welding torch
Control lead for the welding torch
is interrupted.
► Check the control lead for the
welding torch, replace cable
assembly if necessary.
See the operating instructions
for the welding torch
Wire feeder motor does
not run.
Wire feeder motor is defective.
► Replace the wire feeder motor.
See service manual.
The cable connection between the
control board and motor is
interrupted.
► Check the cable connection and
replace it if necessary.
See service manual.
Wire is kinked between
the wire feed roll and
the wire guide tube.
Contact pressure of the wire feed
rolls is too great.
► Adjust the contact pressure.
Distance between the wire guide
tube and the wire feed roll is
too big.
► Check the distance, adjust the
wire guide tube if necessary.