132 Fault tracing
Communication errors
Code
Error
Cause
What to do
8000
EtherCAT AL status code
(_ecETHERCAT_AL_STAT
USCODE)
This error is listed together with a
Profile Code in the Mint WorkBench
Error Log. Note: The displayed
profile code must be converted to
hexadecimal to give the specific
EtherCAT error code.
This error status indicates that the
EtherCAT master has been sent an
error code by the drive. Check the error
log to determine what the "real" drive
error code is.
8001
CIP configuration error
(_ecCIP_CFG_ERROR)
This error is listed together with a
Profile Code in the Mint WorkBench
Error Log. The displayed profile code
must be converted to hexadecimal to
give the specific CIP general status
code.
This error status indicates that the
EtherCAT master has been sent a CIP
error code by the drive. Check the error
log to determine what the "real" drive
error code is.
8002
POWERLINK error code
(_ecPOWERLINK_ERROR)
This error is listed together with a
Profile Code in the Mint WorkBench
Error Log. The displayed profile code
must be converted to hexadecimal to
give the specific POWERLINK error
code.
This error status indicates that the
POWERLINK master has been sent an
error code by the drive. Check the error
log to determine what the "real" drive
error code is.
8003
PROFInet error code
(ecPROFINET_CFG_ERRO
R)
This error is reported when multicast
MAC filter configuration fails.
This error status indicates that the
PROFInet master has tried to configure
the device ID but has failed.
Summary of Contents for MicroFlex e190
Page 1: ...ABB motion control User s manual MicroFlex e190 servo drive ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 26: ...26 Introduction to the manual ...
Page 90: ...90 Electrical installation input output ...
Page 146: ...146 Maintenance ...
Page 178: ...178 Resistor braking ...
Page 186: ...186 Accessories ...
Page 208: ...208 Appendix Safe Torque Off STO ...