Installation checklist 91
8
Installation checklist
Checklist
Check the mechanical and electrical installation of the drive before start-up. Go
through the checklist together with another person.
WARNING!
Only qualified electricians are allowed to carry out the work
described below. Read the safety instructions on the first pages of this manual
before you work on the unit. Ignoring the safety instructions can cause injury or death.
Open the main disconnector of the drive and lock it to open position. Measure to
ensure that the drive is not powered.
Check
MECHANICAL INSTALLATION
The ambient operating conditions are allowable. (See
The unit is fastened properly to the cabinet. (See
and
)
The cooling air will flow freely.
The motor and the driven equipment are ready for start. (See
.)
ELECTRICAL INSTALLATION
(See
Planning the electrical installation, Electrical installation:
AC input / DC input, motor and brake.
)
The capacitors are reformed if stored over one year (ask local ABB representative for
more information).
The drive is grounded properly.
Summary of Contents for MicroFlex e190
Page 1: ...ABB motion control User s manual MicroFlex e190 servo drive ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 26: ...26 Introduction to the manual ...
Page 90: ...90 Electrical installation input output ...
Page 146: ...146 Maintenance ...
Page 178: ...178 Resistor braking ...
Page 186: ...186 Accessories ...
Page 208: ...208 Appendix Safe Torque Off STO ...