Electrical installation: input / output 65
X3: Digital inputs - general purpose DI1 & DI2
These general purpose fast digital inputs are buffered by an opto-isolator, allowing
the input signal to be connected with either polarity. When the MicroFlex e190 is
connected to Mint WorkBench, the digital inputs can be configured using the Digital
I/O tool. Alternatively, Mint keywords including
RESETINPUT
,
ERRORINPUT
,
STOPINPUT
,
FORWARDLIMITINPUT
,
REVERSELIMITINPUT
,
DRIVEENABLEINPUT
,
MOTORTEMPERATUREINPUT
,
PHASESEARCHINPUT
and
HOMEINPUT
can be used.
The state of the digital inputs can be viewed using the Mint WorkBench Spy window's
Axis tab. See the Mint help file for details.
Digital input - typical connections from a PLC/controller:
PLC/controller
X3
16
6
TLP118
10
MicroFlex e190
DI1+
DI1-
Shield
User
supply
24 V
User
supply
GND
Digital input - typical connections from an ABB DO561 PLC output module:
DO561
11
20
19
X3
16
6
10
MicroFlex e190
UP
DI1+
O0
DI1-
Shield
TLP118
ZP
User
supply
24 V
User
supply
GND