![background image](http://html.mh-extra.com/html/abb/microflex-e190/microflex-e190_user-manual_5164062.webp)
+24 V DC
19
X3
9
AI0
(
)
ADC.0
8
0 V
Nȍ:
Nȍ:
potentiometer
62 Electrical installation: input / output
Typical input circuit to provide 0-10 V (approx.) input from a 24 V source:
Analog input - typical connections from a PLC/controller:
Mint
ADC.0
+15V
MicroFlex e190
AI0+
19
X3
9
AI0-
-15V
Shield
PLC/controller
Connect overall shield at one
end only
Analog input - typical connections from an ABB AO561:
Mint
ADC.0
+15V
MicroFlex e190
AI0+
19
X3
9
AI0-
-15V
18
13
O0U+
17
O01-
SG
AO561
Connect overall shield at one
end only