60 Electrical installation: input / output
Connecting the control cables
Wire sizes and tightening torques:
X1A: Dinkle EC762V-B3253206P-BK
X1B: Dinkle EC762V-B3253203P-BK
0.2...6.0 mm
2
(30*...10 AWG)
* Minimum size for UL installations is 14 AWG.
Torque: 0.7 N·m (6.2 lbf·in)
X2: Phoenix Contact MVSTBR 2,5HC/ 2-ST-5,08
0.2...2.5 mm
2
(24...12 AWG)
Torque: 0.6 N·m (5.3 lbf·in)
X3, X4: Weidmüller B2L 3.50/20/180,
Weidmüller B2L 3.50/8/180
0.2...1.0 mm
2
(28...16 AWG)
Notes:
The wiring shown is for demonstrative purposes
only. Complete information for all connectors,
including X7 and X8, is provided in this chapter
and the chapter
E1/E2
Ethernet fieldbus
IN
E2
OUT
E1
X1A
AC input
200...240 V AC ±10%
L1
1
L2
2
L3
3
DC bus-
UDC-
4
Brake-
R-
5
DC bus+ / Brake+
R+/UDC+
6
X1B
Motor output
U
1
V
2
W
3
E3
Ethernet host (PC)
1
X3
X3
1
Status-/DO0-
Status-/DO0+
11
2
DO2-
DO2+
12
3
DO1-
DO1+
13
4
DI2-
DI2+
14
5
DI3-
DI3+
15
6
DI1-
DI1+
16
7
DI0-
DI0+
17
8
AGND
AO0
18
9
AI0-
AI0+
19
10
Shield
Shield
20
E2
E1
X1A
X1B
E3
X3
X4
X8
X7
X2
Feedback voltage
selector
DO0-DO2: Maximum 100 mA per output, R
load
> 250 ohm.
AI0: Differential and single-ended connections are possible.
X4
X4
1
STO1
STO1
5
2
STO2
STO2
6
3
SGND
SGND
7
4
24 V out
24 V out
8
Safe Torque Off: Both circuits must be closed for the drive to start.
X2
(Optional) Control circuit
supply input: 24 V, 1 A
0 V
1
+24 V IN
2
M
Summary of Contents for MicroFlex e190
Page 1: ...ABB motion control User s manual MicroFlex e190 servo drive ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 26: ...26 Introduction to the manual ...
Page 90: ...90 Electrical installation input output ...
Page 146: ...146 Maintenance ...
Page 178: ...178 Resistor braking ...
Page 186: ...186 Accessories ...
Page 208: ...208 Appendix Safe Torque Off STO ...