Technical data 151
Supply cable fuses
Fuses for short circuit protection of the supply cable are listed below. The fuses also
protect the adjoining equipment of the drive in case of a short circuit. Check that the
operating time of the fuse is below 0.5 seconds. The operating time depends on the
supply network impedance and the cross-sectional area and length of the supply
cable. See also chapter
Planning the electrical installation
.
Note:
Fuses with a higher current rating must not be used
1
Φ
AC supply
3
Φ
AC supply
Drive type
MFE190-04
xx
...
Input
current
(A)
IEC fuse
UL fuse
Cross-sectional
area of cable
Rated
current
(A)
Voltage
(V)
Class Rated
current
(A)
Voltage
(V)
UL
Class
mm
2
AWG
-01A6-2
3
20
500
gG
20
600
CC
1.5...4
16…12
-03A0-2
7
500
gG
600
1.5...4
16…12
-06A0-2
14
500
gG
600
1.5...4
16…12
-09A0-2
20
500
gG
600
1.5...6
16…10
Drive type
MFE190-04
xx
...
Input
current
(A)
IEC fuse
UL fuse
Cross-sectional
area of cable
Rated
current
(A)
Voltage
(V)
Class Rated
current
(A)
Voltage
(V)
UL
Class
mm
2
AWG
-01A6-2
2
20
500
gG
20
600
CC
1.5...4
16…12
-03A0-2
4
500
gG
600
1.5...4
16…12
-06A0-2
8
500
gG
600
1.5...4
16…12
-09A0-2
12
500
gG
600
1.5...6
16…10
Summary of Contents for MicroFlex e190
Page 1: ...ABB motion control User s manual MicroFlex e190 servo drive ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 26: ...26 Introduction to the manual ...
Page 90: ...90 Electrical installation input output ...
Page 146: ...146 Maintenance ...
Page 178: ...178 Resistor braking ...
Page 186: ...186 Accessories ...
Page 208: ...208 Appendix Safe Torque Off STO ...