Periodic check of the calibration tool
If including the calibration tool in a local periodic check system, the following
measures should be checked.
•
Outer diameter within Ø12g4 mm, Ø8g4 mm or Ø6g5 mm (depending on
calibration tool size).
•
Straightness within 0.005 mm.
xx1500000951
Outer diameter
A
Product manual - IRT 710
349
3HKA00000186299-001 Revision: B
© Copyright 2023 ABB. All rights reserved.
6 Calibration
6.4.2 Calibration tools for Axis Calibration
Continued